Troubleshooting
This article outlines common problems while upgrading RapidMiner Server.
Timeout during RapidMiner Server start
You might see the following log lines in the server.log
file within the
RapidMiner Server home directory:
ERROR [org.jboss.as.controller.management-operation] (Controller Boot Thread) JBAS013412: Timeout after [300] seconds waiting for service container stability. Operation will roll back. Step that first updated the service container was 'add' at address '[
("core-service" => "management"),
("management-interface" => "native-interface")
]'
ERROR [org.jboss.as.controller.client] (Controller Boot Thread) JBAS014781: Step handler org.jboss.as.server.DeployerChainAddHandler$FinalRuntimeStepHandler@2821a6c1 for operation {"operation" => "add-deployer-chains","address" => []} at address [] failed handling operation rollback -- java.util.concurrent.TimeoutException
Explanation: JBoss requires a lot of time to start after the initial upgrade and then times out. This can happen because a column has been added in the new version and the existing table needs to be migrated. When such tables are large, the migration can take a lot of time and exceed the JBoss deployment time which is 300 seconds by default.
Solution: The property jboss.as.management.blocking.timeout
is used to determine how long a deployment might
take before JBoss aborts the deployment. A solution to the problem is to temporarily increase the default timeout.
Please use the following statement (.bat
on Windows) to start RapidMiner Server for a temporary timeout increase:
./bin/standalone.sh -Djboss.as.management.blocking.timeout=3600
. After the upgrade completed successfully the timeout
increase is not required anymore.
Overlapping Job Container ports on a single host
With RapidMiner Server 9.5 the Job Container architecture changed fundamentally and requires system ports for the Job Agent to Job Container communication which are only used locally on the machine on which the Job Agent is deployed.
In case multiple Job Agents are hosted on a single shared machine, the definition of duplicate ports might result in the following log lines:
Job container '1' cannot be spawned, because port '10000' is not available
Job container '1' started successfully with PID 'null'.
Such a scenario occurs when multiple Job Agents define the same value for the jobagent.container.listenPortRangeStart
property and are hosted on a single machine. To overcome this problem, ensure to define distinct port start ranges for
each deployed Job Agent on the same machine to avoid overlapping ports of Job Containers.